Inicio >Productos >banco de carga
Banco de carga resistiva de 2000 kW con probador de generador para pruebas de generador
Banco de carga resistiva de 2000 kW con probador de generador para pruebas de generador
  • Detail
  • Order


TUV-Rheinland-CE-certificate.jpg


KEYPOWER generator tester specifications

MeasurementRangeAccuracyResolutionOverload
Voltage (V)10.0~500.0V±   (0.4% reading+0.1%range)0.1V600V
Current (A)0.030~5.000A ±   (0.4% reading+0.1%range)0.001A6A
powerAccording   to volt range &  current rangePower   factor=1.0
≥200W 1W
± (0.4% reading+0.1% range)≥2kW 10W
Power factor=0.5<200W 0.1W
± (0.8% reading+0.2% range)
Power factor
0.20~1.00
±0.02
0.001

Frequency
45~65Hz
±0.2Hz
0.01Hz

Running time
99h59m
±2min/hour
1   minute

Energy
(kWh)
99999kWh Power   factor=1.00.001kwh
± (0.4% reading+0.1% range)
Power factor=0.5
± (0.8% reading+0.2% range)
Harmonic analysis (%)2-50   times and total harmonic




Specifications

100-5000KW Load Bank for Generator Load Test:

1.Premium components

2.Durable and reliable

3.Easy to transport 


Load bank is a simulating load test equipment used for 

generators, UPS, battery banks etc power systems load test. 

1. Resistive type of load, PF = 1.0. Stainless steel sheathed elements manufactured from high grade magnesium oxide.
2Rated testing voltage : AC 3P4W, 110-480V 50/60 Hz. standard, special one on request.
3. Cooling mode: Forced air-cooled, fans mounted on the side of the load bank blow horizontally. Testing power or external utility power supply for fans. 
4. Working mode: Load step control
Total testing capacity ranges from 0kw to the max consisting of 10kw, 20kw, 50kw, 100kw load setting switches plus a 0-10kw fine-tuning knob. From 0kw to the max, any load combination is achievable. Load step resolution is 10kw. 
5. Load bank features world-famous components to ensure reliable performance and longer service life including:
SCHNEIDER contactors. 
Siemens switches, knobs and indicators. 
ABB Circuit breakers. 
OMRON intermediate relays. 
PHOENIX terminal blocks. 
6.  Parameter measuring accuracy grade: 0.3 
7. Load control accuracy: ± 5%. 
8. Load bank protections: Over heating protection, cooling fans failure protection and over load protection with alarm. 
9. Control mode: Two control modes available:
A)Local manual control;
B)Optional: Manual control via a remote control panel (max control distance is 30m). 
10. Parameter display and measurement:
Control panel contains a LOVATO Multifunction Electricity Meter displaying voltage, current, load power, reactive power, apparent power, power factor, frequency etc.
(Optional: A professional generator tester displays and measures all sorts of steady, dynamic parameters as well as harmonic wave, can be connected to a PC for data recording and test report printing). " 
11. Operating environment:
Altitude: ≤ 3000m above sea level. Ambient temp: -10~+50 ℃
Relative humidity: ≤ 80% ventilated environment without explosive or corrosive dust. Not allowed to use in rainy outdoor environment.